Asymmetrical K-Joint has the following variables:
VARIABLE EFFECT ON THE CALCULATION? EFFECT ON DRAWING OF THE JOINT? LIMITATIONS IN VALUE?
  • Plate thickness
  • YES YES >0
  • Root Gap
  • YES YES >=0
  • Root Face
  • YES YES Root Face/2 <= (Platethickness - Distance to Center of Root Face).
    Root face >= 0
  • Included Angle
  • YES YES >= 0 <90
  • Height of Cap side 1
  • YES YES >=0,01
  • Height of Cap side 2
  • YES YES >=0,01
  • Layer thickness
  • NO YES NO
  • Included Angle Side 2 
  • YES YES >= 0 <90
  • Distance to center of root face. 
  • YES YES Distance to center of root face <= (Platehickness - Root Face/2).
    Distance to center of root face >= 0
     